Overview

Product Name:Incubators Green Line

Incubators (refrigerated andnon-refrigerated thermostats),thermostatic baths (GreenLine) and chambers forpharmaceutical stability tests (with or without photoperiod control) and growthchambers are the primary instrument...

Features

In order to satisfy thedifferent needs of thermostatting and intended use, the range of incubatorsoffered by KW is extremely wide. Incubators are generally able to operate fromambient temperature (or from +5°C for the refrigerated ones) to +70°C maximum.
In all equipment above mentioned, the THERMOSTATTING can be obtained throughdifferent modes of air /liquid circulation:natural convection, guidedcirculation, forced circulation.
WI series incubators are withguided circulation,whereas all the others, WPLR, W-LAB, WR-LAB,and WRC, arewith forced circulation.

Model

External
dimensions (WxDxH)

Internal
dimensions (WxDxH)

Capacity
(lt)

No. of
Shelves

Max No. of
Shelves

Range of
adjustment (*)

Precision at
37°C

Power
(W)

Weight
(KG)

WI 6

cm.38x24x30 h

cm. 19x15x19 h

6

2

4

+80°C

± 2 %

120

10

WI 18

cm.50x39x32 h

cm. 30x30x20 h

19

2

5

+80°C

± 2 %

360

15

WI 30

cm.62x36x44 h

cm. 40x25x30 h

30

2

5

+80°C

± 2 %

420

24.5


Incubators with water jacketW90 and W102.These series of incubators have an internal heating system withwater jacket, without internal forced ventilation; in this way the risk of soildehydration and possible cross contamination no longer exist.Water jacketensures temperature stability and uniformity.

Model

External
dimensions (wxdxh)

Internal
Dimensions (wxdxh)

Capacity

Shelves

Range of
adjustment

Stability T

Power
installed

Weight

W90

cm. 70x62x100 h

cm. 53x44x60 h

litri 140

n.2

* up to +55°C

±0,1°C

Kw. 1

Kg. 90

W102

cm. 126x62x100 h

cm. 110x44x60 h

litri 290

n.2

* up to+55°C

±0,1°C

Kw. 2

Kg. 140

WR 90

cm. 70x62x165 h

cm. 53x44x60 h

litri 140

n.2

+10°C +55°C

<±0,5°C

Kw. 1,4

Kg. 130

WR 102

cm. 126x62x170 h

cm. 110x44x60 h

litri 290

n.2

+10°C +55°C

<±0,5°C

Kw. 2,6

Kg. 200


Refrigeratedincubators WR-LAB, WPLR, WRC are highly sophisticated appliances suitable formultiple applications; in industrial laboratories, healthcenter,etc..

Modello

External
dimensions (WxDxH)

Capacity

Shelves
n.

Door

Stability T

Uniformity T

T range

Nominal power
(installed)

Weight

WRC 700

cm. 72x80x202 h

litres 700

3

blind

± 0,5°C

± 0,5°C

0°C to +50°C

W 750

Kg. 120

WRC 1500

cm. 144x80x202 h

litres 1500

6

blind

± 0,5°C

± 0,5°C

0°C to +50°C

W 900

Kg. 200

WRV 700

cm. 72x80x202 h

litres 700

3

glass

± 0,5°C

± 0,5°C

0°C to +50°C

W 750

Kg. 130

WRV 1500

cm. 144x80x202 h

litres 1500

6

glass

± 0,5°C

± 0,5°C

0°C to +50°C

W 900

Kg. 210


Thermostatic baths (W80-W82,W82/O, W84/O and special water baths) that are based on a thermoregulated bath(with or without agitation) through liquid circulation.

Model

External
dimensions

Internal
dimensions

Capacity

Range of
adjustment

Precision

Power supply

Power
(installed)

Weight

W.80
table operated

cm. 48x32x28 h

cm. 30x23x14 h

9 litres

Up to and over
+95°C

±0,1°C

V220 Hz 50

KW. 0,75

Kg. 15

W.82
table operated

cm. 71x44x35 h

cm. 40x35x20 h

28 litres

Up to and over
+95°C

±0,1°C

V220 Hz 50

KW. 1,5

Kg. 32


Chambers for environmentalsimulation: WR UR 700C chambers for pharmaceutical stability tests and WRS 96and WRS 85 photoperiod control for plant toxicity and growth tests.

Model

External
dimensions (WxDxH)

Internal
dimensions (WxDH)

Capacity
(lt)

No. of
Shelves

Range of
adjustment(*)

Power
(W)

Weight
(KG)

WR UR700C HPL

cm. 71x80x200 h

cm. 59x68x125 h

700

4

+20°C to +50°C

1500

160

TEMPERATURE (T) STABILITY AND UNIFORMITY: < ±1.5°C
RELATIVE HUMIDITY (RH) STABILITY AND UNIFORMITY: < ±5%
The T fi eld is between +20°C and +50°C
The RH fi eld is between 30% and 80%


When choosing the instrument,it is also necessary to know the required type of temperature control, whetheror not freely programmable temperature profi les are necessary, or if a heatingsystem for predetermined temperatures and times is enough.
Analyses at temperatures between 0°C and ambient temperature are carried out inbiotechnological research, in the food, pharmaceutical and cosmetic industry,or in all fi elds that require an extremely precise temperature control,anexcellent repeatability and the documentation of analysis processes.

Technical Parameters

Application field

Main accessories

Video

Follow Us
Phone
8621-60877093‬‬

Email:info@zaotonghk.com
Address:Room 616, Shihe Business Center, No. 1 Lane 2277, Zuchongzhi Road, Pudong New Area, Shanghai