Features
In order to satisfy thedifferent needs of thermostatting and intended use, the range of incubatorsoffered by KW is extremely wide. Incubators are generally able to operate fromambient temperature (or from +5°C for the refrigerated ones) to +70°C maximum.
In all equipment above mentioned, the THERMOSTATTING can be obtained throughdifferent modes of air /liquid circulation:natural convection, guidedcirculation, forced circulation.
WI series incubators are withguided circulation,whereas all the others, WPLR, W-LAB, WR-LAB,and WRC, arewith forced circulation.
Model
|
External
dimensions (WxDxH)
|
Internal
dimensions (WxDxH)
|
Capacity
(lt)
|
No. of
Shelves
|
Max No. of
Shelves
|
Range of
adjustment (*)
|
Precision at
37°C
|
Power
(W)
|
Weight
(KG)
|
WI 6
|
cm.38x24x30 h
|
cm. 19x15x19 h
|
6
|
2
|
4
|
+80°C
|
± 2 %
|
120
|
10
|
WI 18
|
cm.50x39x32 h
|
cm. 30x30x20 h
|
19
|
2
|
5
|
+80°C
|
± 2 %
|
360
|
15
|
WI 30
|
cm.62x36x44 h
|
cm. 40x25x30 h
|
30
|
2
|
5
|
+80°C
|
± 2 %
|
420
|
24.5
|
Incubators with water jacketW90 and W102.These series of incubators have an internal heating system withwater jacket, without internal forced ventilation; in this way the risk of soildehydration and possible cross contamination no longer exist.Water jacketensures temperature stability and uniformity.
Model
|
External
dimensions (wxdxh)
|
Internal
Dimensions (wxdxh)
|
Capacity
|
Shelves
|
Range of
adjustment
|
Stability T
|
Power
installed
|
Weight
|
W90
|
cm. 70x62x100 h
|
cm. 53x44x60 h
|
litri 140
|
n.2
|
* up to +55°C
|
±0,1°C
|
Kw. 1
|
Kg. 90
|
W102
|
cm. 126x62x100 h
|
cm. 110x44x60 h
|
litri 290
|
n.2
|
* up to+55°C
|
±0,1°C
|
Kw. 2
|
Kg. 140
|
WR 90
|
cm. 70x62x165 h
|
cm. 53x44x60 h
|
litri 140
|
n.2
|
+10°C +55°C
|
<±0,5°C
|
Kw. 1,4
|
Kg. 130
|
WR 102
|
cm. 126x62x170 h
|
cm. 110x44x60 h
|
litri 290
|
n.2
|
+10°C +55°C
|
<±0,5°C
|
Kw. 2,6
|
Kg. 200
|
Refrigeratedincubators WR-LAB, WPLR, WRC are highly sophisticated appliances suitable formultiple applications; in industrial laboratories, healthcenter,etc..
Modello
|
External
dimensions (WxDxH)
|
Capacity
|
Shelves
n.
|
Door
|
Stability T
|
Uniformity T
|
T range
|
Nominal power
(installed)
|
Weight
|
WRC 700
|
cm. 72x80x202 h
|
litres 700
|
3
|
blind
|
± 0,5°C
|
± 0,5°C
|
0°C to +50°C
|
W 750
|
Kg. 120
|
WRC 1500
|
cm. 144x80x202 h
|
litres 1500
|
6
|
blind
|
± 0,5°C
|
± 0,5°C
|
0°C to +50°C
|
W 900
|
Kg. 200
|
WRV 700
|
cm. 72x80x202 h
|
litres 700
|
3
|
glass
|
± 0,5°C
|
± 0,5°C
|
0°C to +50°C
|
W 750
|
Kg. 130
|
WRV 1500
|
cm. 144x80x202 h
|
litres 1500
|
6
|
glass
|
± 0,5°C
|
± 0,5°C
|
0°C to +50°C
|
W 900
|
Kg. 210
|
Thermostatic baths (W80-W82,W82/O, W84/O and special water baths) that are based on a thermoregulated bath(with or without agitation) through liquid circulation.
Model
|
External
dimensions
|
Internal
dimensions
|
Capacity
|
Range of
adjustment
|
Precision
|
Power supply
|
Power
(installed)
|
Weight
|
W.80
table operated
|
cm. 48x32x28 h
|
cm. 30x23x14 h
|
9 litres
|
Up to and over
+95°C
|
±0,1°C
|
V220 Hz 50
|
KW. 0,75
|
Kg. 15
|
W.82
table operated
|
cm. 71x44x35 h
|
cm. 40x35x20 h
|
28 litres
|
Up to and over
+95°C
|
±0,1°C
|
V220 Hz 50
|
KW. 1,5
|
Kg. 32
|
Chambers for environmentalsimulation: WR UR 700C chambers for pharmaceutical stability tests and WRS 96and WRS 85 photoperiod control for plant toxicity and growth tests.
Model
|
External
dimensions (WxDxH)
|
Internal
dimensions (WxDH)
|
Capacity
(lt)
|
No. of
Shelves
|
Range of
adjustment(*)
|
Power
(W)
|
Weight
(KG)
|
WR UR700C HPL
|
cm. 71x80x200 h
|
cm. 59x68x125 h
|
700
|
4
|
+20°C to +50°C
|
1500
|
160
|
TEMPERATURE (T) STABILITY AND UNIFORMITY: < ±1.5°C
RELATIVE HUMIDITY (RH) STABILITY AND UNIFORMITY: < ±5%
The T fi eld is between +20°C and +50°C
The RH fi eld is between 30% and 80%
|
When choosing the instrument,it is also necessary to know the required type of temperature control, whetheror not freely programmable temperature profi les are necessary, or if a heatingsystem for predetermined temperatures and times is enough.
Analyses at temperatures between 0°C and ambient temperature are carried out inbiotechnological research, in the food, pharmaceutical and cosmetic industry,or in all fi elds that require an extremely precise temperature control,anexcellent repeatability and the documentation of analysis processes.